About Me

Dr. Molham M. Eyadeh

Associate professor in Physics

                                       

Address: Yarmouk University

                 Faculty of Science  

                 Physics Department 

                 Irbid, 21163, Jordan

 

Tel:              00962790276510

 

Email:                molhem.e@yu.edu.jo

                     

 

Personal:

Citizenship:            Jordan.

Date of Birth:         16/06/1981

Marital Status:        Married 

 

 

 

Education:

 

 

Particulars

 

 

Bachelor

 

Master

 

Doctorate

 

Field

 

Specific specialization

 

 

 

 

 

 

Year

 

 

 

Institution

 

 

Place

 

Physics

 

Physics

 

 

 

 

 

 

 

2003

 

 

Yarmouk  University

 

 

Jordan

 

Physics

 

Physics

 

 

 

 

 

 

 

2009

 

 

Yarmouk University

 

 

Jordan

 

Medical Physics

 

Medical Physic and Applied Radiation Sciences

(Medical Dosimetry)

 

 

2016

 

 

McMaster University

 

 

Canada

 

 

 

 

 

 

Titles of theses:

PhD thesis

The Development of a Transparent Poly (vinyl alcohol) Radiochromic Cryogel Dosimeter and Optical Detection Methods

McMaster University, Hamilton, Ontario, Canada, 2016.

 

MSc thesis

Coincidence Summing Corrections for Marinelli-Beakers Geometry in HPGe Gamma Ray Spectrometry Using Peak to Total (P/T) Calibration

Yarmouk University, Irbid, Jordan, 2009.

 

 

Experience:

31 Jan 2016- 15 June 2020, Assistant Professor (Physics)

16 June 2020 – Present, Associate Professor (Physics)

Yarmouk University, Faculty of science, Physics department. Irbid, Jordan.

 

02 Oct 2022- Present, Associate Professor (Medical Physics), Sabbatical leave- Medical Imaging department, Faculty of Applied Medical Sciences, The Hashemite University, Zarqa, Jordan. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Teaching Experience (Bachelors and Masters)

 

·      Classical physics

·      Quantum physics

·      Electromagnetic physics

·      Modern physics

·      Electronics

·      Health physics

·      Radiobiology

·      Radiotherapy physics

·      Nuclear Medicine

·      Medical Imaging

·      Digital Image Processing

·      Quality Control of Radiography

·      General Physics (Classical and EM)

 

Research Experience: (Supervisung more than ten physics students )

 

My research focuses on the field of medical physics including:

Radiation dosimetry (Polymer and radio-chrmic gel dosimters  and radio-chrmoic film dosimters). 

. Radiation therapy

 

 

Funding Research:

"Developing of chemical dosimeters of radiation doses in conjunction with charge coupled device (CCD) camera"

 

Supported by the Deanship of Research and Graduate

studies at Yarmouk University, Irbid, Jordan. Grant number 3/2017.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conferences:

1-

Conference

Canadian Organization of Medical Physicists Annual Scientific Meeting

Country

Canada

Date

September 2013

Research Title

Evaluation of a ferrous benzoic xylenol orange transparent PVA cryogel radiochromic dosimeter

Authors

Molham M Eyadeh, Thomass Farrell, Kevin R Diamond

Nature of contribution

Oral

 

2-

conference

EMN meeting on Hydrogel Materials

Country

Singapore

Date

May 2016

Research Title

Translucent Poly(vinyl alcohol) Cryogel Dosimeters for Simultaneous Dose Build up and Monitoring During Chest wall Radiation Therapy

Authors

Molham M Eyadeh, Mark A Weston, Janos Juhasz, Kevin R Diamond

Nature of contribution

Oral

 

3-

Conference

World Congress on Medical Physics and Biomedical Engieering

Country

Canada

Date

June 2015

Research Title

Evaluation of surface dose distributions using ferrous benzoic xylenol orange translucent PVA cryogel radiochromic dosimeters

Authors

Molham M Eyadeh, Marcin Wierzbicki, Kevin R Diamond

Nature of contribution

Oral

 

 

 

 

 

 

 

 

 

Link to google Scholar,  Scopus profiles, Researchgate, and ORCID

 

https://scholar.google.com/citations?user=jmAC-I4AAAAJ&hl=en

 

https://www.scopus.com/authid/detail.uri?authorId=56074409800

 

https://www.researchgate.net/profile/Molham-Eyadeh

 

https://orcid.org/0000-0003-4997-0326

 

 

 

 

 

 

 

 

 

 

 

Publications:

Eyadeh, M.M., Rabaeh, K.A., Issa, A.S. and Diamond, K.R., 2023. Evaluation of a novel N-(Hydroxymethyl) acrylamide polymer gel dosimeter formulation with organic glucose additive for radiotherapy. Radiation Measurements, p.106983.

 

Rabaeh, K. A., Eyadeh, M. M., Alshomali, L. S., Aldweri, F. M., & Oglat, A. A. (2023). Optical characterization of Fricke-methylthymol blue hydrogel dosimeter with gellan gum as physical cross-linker. Journal of Radioanalytical and Nuclear Chemistry, 1-9.

 

Rabaeh, K.A., Al-Zawaydaih, H.H., Eyadeh, M.M. and Shatnawi, M.T., 2022. High optical stability of reusable radiochromic polyvinyl alcohol-iodine gel dosimeter for radiotherapy. Radiation Physics and Chemistry, p.110338.

 

Rabaeh, K. and Eyadeh, M., 2022. Optical properties of polymerization N-(3-methoxypropyl) acrylamide polymer gel dosimeters for radiotherapy. Pigment & Resin Technology, (ahead-of-print).

 

Rabaeh, K.A., Hammoudeh, I.M. and Eyadeh, M.M., 2022. Novel polymer gel dosimeters based on N-Vinylcaprolactam for medical dosimetry. Journal of Radioanalytical and Nuclear Chemistry, pp.1-7.

 

Rabaeh, K.A., Al-Tarawneh, R.E., Eyadeh, M.M., Hammoudeh, I.M. and Shatnawi, M., 2022. Improved Dose Response of N(Hydroxymethyl) acrylamide Gel Dosimeter with Calcium Chloride for Radiotherapy. Gels, 8(2), p.78.  

 

Eyadeh, M.M., Alshomali, L.S., Rabaeh, K.A., Oglat, A.A. and Diamond, K.R., 2022. Improvement on the performance N-(3-methoxypropyl) acrylamide polymer-gel dosimeter by the addition of inorganic salt for application in radiotherapy dosimetry. Journal of Radioanalytical and Nuclear Chemistry, pp.1-9.

 

Rabaeh, K.A., Hammoudeh, I.M., Moftah, B., Oglat, A.A., Eyadeh, M.M., Aldweri, F.M., Abdel-Qader, A.J. and Devic, S., 2022.A normoxic acrylic acid polymer gel for dosimetery in radiation therapy. Journal of Radioanalytical and Nuclear Chemistry, pp.1-8.

 

Eyadeh, M.M., Smadi, S.A., Rabaeh, K.A., Oglat, A.A. and Diamond, K.R., 2021. Effect of lithium chloride inorganic salt on the performance of N-(Hydroxymethyl) acrylamide polymer-gel dosimeter in radiation therapy. Journal of Radioanalytical and Nuclear Chemistry, 330(3),  pp.1255-1261.

 

Rabaeh, K.A., Issra’ME, H., Oglat, A.A., Eyadeh, M.M., Ala'J, A.Q., Aldweri, F.M. and Awad, S.I., 2021. Polymer gel containing N, N′-methylene-bis-acrylamide (BIS) as a single monomer for radiotherapy dosimetry. Radiation Physics and Chemistry, 187, p.109522.

Rabaeh, K.A., Aljammal, S.A., Eyadeh, M.M. and Abumurad, K.M., 2021. Methyl thymol blue solution and film dosimeter for high dose measurements. Results in Physics, 23, p.103980.

Rabaeh, K.A., Issra’ME, H., Eyadeh, M.M., Aldweri, F.M., Awad, S.I., Oglat, A.A. and Shatnawi, M.T., 2021. Improved performance of N-(Hydroxymethyl) acrylamide gel dosimeter using potassium chloride for radiotherapy. Radiation Measurements, 142, p.106542.

Rabaeh, K.A., Salman, N.M.B., Aldweri, F.M., Saleh, H.H., Eyadeh, M.M., Awad, S.I. and Oglat, A.A., 2021. Substantial influence of magnesium chloride inorganic salt (MgCl2) on the polymer dosimeter containing N-(Hydroxymethyl) acrylamide for radiation therapy. Results in Physics, 22, p.103862.

 

Rabaeh, K.A., Eyadeh, M.M., Hailat, T.F., Madas, B.G., Aldweri, F.M., Almomani, A.M. and Awad, S.I., 2021. Improvement on the performance of chemically cross-linked fricke methylthymol-blue radiochromic gel dosimeter by addition of dimethyl sulfoxide. Radiation Measurements, 141, p.106540

 

Rabaeh, K.A., Hailat, T.F., Eyadeh, M.M., Al-Shorman, M.Y., Aldweri, F.M., Alheet, S.M., Madas, B.G. and Awad, S.I., 2020. Dosimetric properties of sulfosalicylic acid-ferrous-polyvinyl alcohol-glutaraldehyde hydrogel dosimeters using magnetic and optical techniques. Radiation Physics and Chemistry, 177, p.109106.

 

Zahrany, A.A., Rabaeh, K., Eyadeh, M. and Basfar, A., 2020. Dosimetric evaluation of methyl red radiochromic film for radiation processing. Pigment & Resin Technology.

 

Abdallah, M.J., Eyadeh, M.M., Hamadneh. H.H., Akour, A.N., Hawamdeh, M.M., Almaaitah, I.F.,  2019. Radiological characterization of settled dust during a severe dust episode in the Middle East. Jordan Journal of Physics. 12 (2), 183-189.

 

Eyadeh,  M.M.,  Rabaeh,  K.A., Aldweri,  F.M., Al- Shorman, M.Y., Alheet,  S.M., Awad, S.I., Hailat, T.F.,  2019. Nuclear magnetic resonance analysis of a chemically cross-linked ferrous–methylthymol blue–polyvinyl alcohol radiochromic gel dosimeter. Applied Radiation and Isotopes. 153, 108812.

 

Awad, S.I., Moftah, B., Basfer, A.,  Almousa, A.A., Al Kafi, A., Eyadeh, M.M., Rabaeh, K.A., 2019. 3-D Quality Assurance in CyberKnife Radiotherapy Using a Novel N-(3-methoxypropyl) Acrylamide Polymer Gel Dosimeter and Optical CT. Radiation Physics and Chemistry. 161, 34-41.

 

Rabaeh, k. A., Al-Ajaleen, M. S., Abuzayed, M. H., Aldweri, F. M., Eyadeh, M. M., 2019. High dose sensitivity of N-(isobutoxymethyl)acrylamide erpolym gel dosimeters with improved monomer solubility using acetone co-solvent. Nuclear Inst. and Methods in Physics Research B. 442, 67–72.

 

Eyadeh, M M., Rabaeh, K A., Hailat, T. F., Aldweri, F. M., 2018. Evaluation of ferrous Methylthymol blue gelatin gel dosimeters using nuclear magnetic resonance and optical techniques. Radiation mesurements, 108, 26-33.

 

Eyadeh, M M., Rabaeh, K A., Hailat, T F., Al-Shorman, M Y. 2018.  Investigation of a novel chemically cross-linked fricke-Methylthymol blue-synthetic polymer gel dosimeter with glutaraldehyde cross-linker. Radiation Measurements. 118,  77-85.

 

Rabaeh, K. A., Eyadeh, M. M., Hailat, T. F., Aldweri, F. M., Alheet, S. M., Eid, R. M., 2018. Characterization of ferrous-methylthymol blue-polyvinyl alcohol gel dosimeters using nuclear magnetic resonance and optical techniques. Radiation Physics and Chemistry.148, 25-32.

 

Hamadneh , H., Eyadeh, M., Abdallah M., AlKhdirat, O., 2017.  Estimation of Natural and Anthropogenic Exposures to Gamma Ray from a High Agricultural Area in Jordan "Bani-Kananah District. Jordan Journal of Physics. 10, 117-125.

 

Eyadeh, M.M., Wierzbicki, M., Diamond, K.R., 2017. Measurement of skin surface dose distributions in radiation therapy using poly(vinyl alcohol) cryogel dosimeters. J. Appl. Clin. Med. Phys. 18, 153–162.

 

Eyadeh, M.M., Wierzbicki, M., Diamond, K.R., 2017. Measurements of superficial dose distributions in radiation therapy using translucent cryogel dosimeters. Journal of Physics: Conference Series 847 (1), 012035.

 

Eyadeh, M.M., Weston, M.A., Juhasz, J., Diamond, K.R., 2016. Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy. J. Appl. Clin. Med. Phys. 17 (5), 308–319.

 

Ababneh A.M., Eyadeh, M.M., 2015. Coincidence summing corrections in HPGe gamma-ray spectrometry for Marinelli-beakers geometry using peak to total (P/T) calibration. Journal of Radiation Research and Applied Sciences. 8,  323-327.

 

Eyadeh, M.M., Farrell, T.J., Diamond, K.R., 2014. Evaluation of a ferrous benzoic xylenol orange transparent PVA cryogel radiochromic dosimeter. Phys Med Biol. 59, 1773–1787.